• AI글쓰기 2.1 업데이트
  • AI글쓰기 2.1 업데이트
  • AI글쓰기 2.1 업데이트
  • AI글쓰기 2.1 업데이트
PARTNER
검증된 파트너 제휴사 자료

TRNSYS 건물 에너지 시뮬레이션 모델 캘리브레이션: GenOpt를 이용한 사례 연구 (A Model Calibration for Residential Building Energy Simulation : A Case Study with TRNSYS and Optimization Tool GenOpt)

12 페이지
기타파일
최초등록일 2025.05.25 최종저작일 2019.08
12P 미리보기
TRNSYS 건물 에너지 시뮬레이션 모델 캘리브레이션: GenOpt를 이용한 사례 연구
  • 미리보기

    서지정보

    · 발행기관 : 한국건축친환경설비학회
    · 수록지 정보 : 한국건축친환경설비학회 논문집 / 13권 / 4호 / 234 ~ 245페이지
    · 저자명 : 임흥빈, 이경호, 공민석, 서동현

    초록

    This paper demonstrates a calibration methodology for adjusting model parameters and factors using assistant tools ― python and GenOpt. In this study, a building simulation model is developed for a demonstration building for a low-energy solar house. The model is composed of a 3D model describing building architecture and HVAC system model using TRNSYS simulation program.
    In this study, model calibration methodology consists of two phases in order to improve the accuracy of building energy model and reduce errors of simulation results: Parameter adjustment phase and factor optimization phase. Trial and error approach is used for the first phase and GenOpt tool is employed for the second phase to improve the model performance. Based on American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) Guideline 14 indices, the performance of the calibrated building simulation model is evaluated to obtain Normalized Mean Bias Error (NMBE)hourly, values within ±10% and Coefficient Variation of Root Mean Square Error (CV (RMSE))hourly, values within 30%. The performance indices are calculated with simulated and measured temperatures of each indoor zone and buffer tank.
    Daily data is used for calibrating heat pump (HP) electrical energy consumption because it is hard to fit the operating time of HP which can be different to time that heating load occurs. As a result of the calibration process, it is found that the values of NMBEhourly and CV (RMSE)hourly achieves within followings: Average indoor temperature 一 NMBEhourly is 1.2% and CV (RMSE)hourly is 2.2%. Buffer tank temperature NMBEhourly is 1.5% and CV (RMSE)hourly is 8.2%.
    And the value of NMBEdaily and CV (RMSE)daily are used for HP electrical use as following: NMBEdaily is 9.5%, CV (RMSE) is 23.4%.

    영어초록

    This paper demonstrates a calibration methodology for adjusting model parameters and factors using assistant tools ― python and GenOpt. In this study, a building simulation model is developed for a demonstration building for a low-energy solar house. The model is composed of a 3D model describing building architecture and HVAC system model using TRNSYS simulation program.
    In this study, model calibration methodology consists of two phases in order to improve the accuracy of building energy model and reduce errors of simulation results: Parameter adjustment phase and factor optimization phase. Trial and error approach is used for the first phase and GenOpt tool is employed for the second phase to improve the model performance. Based on American Society of Heating, Refrigerating and Air-conditioning Engineers (ASHRAE) Guideline 14 indices, the performance of the calibrated building simulation model is evaluated to obtain Normalized Mean Bias Error (NMBE)hourly, values within ±10% and Coefficient Variation of Root Mean Square Error (CV (RMSE))hourly, values within 30%. The performance indices are calculated with simulated and measured temperatures of each indoor zone and buffer tank.
    Daily data is used for calibrating heat pump (HP) electrical energy consumption because it is hard to fit the operating time of HP which can be different to time that heating load occurs. As a result of the calibration process, it is found that the values of NMBEhourly and CV (RMSE)hourly achieves within followings: Average indoor temperature 一 NMBEhourly is 1.2% and CV (RMSE)hourly is 2.2%. Buffer tank temperature NMBEhourly is 1.5% and CV (RMSE)hourly is 8.2%.
    And the value of NMBEdaily and CV (RMSE)daily are used for HP electrical use as following: NMBEdaily is 9.5%, CV (RMSE) is 23.4%.

    참고자료

    · 없음
  • 자주묻는질문의 답변을 확인해 주세요

    해피캠퍼스 FAQ 더보기

    꼭 알아주세요

    • 자료의 정보 및 내용의 진실성에 대하여 해피캠퍼스는 보증하지 않으며, 해당 정보 및 게시물 저작권과 기타 법적 책임은 자료 등록자에게 있습니다.
      자료 및 게시물 내용의 불법적 이용, 무단 전재∙배포는 금지되어 있습니다.
      저작권침해, 명예훼손 등 분쟁 요소 발견 시 고객센터의 저작권침해 신고센터를 이용해 주시기 바랍니다.
    • 해피캠퍼스는 구매자와 판매자 모두가 만족하는 서비스가 되도록 노력하고 있으며, 아래의 4가지 자료환불 조건을 꼭 확인해주시기 바랍니다.
      파일오류 중복자료 저작권 없음 설명과 실제 내용 불일치
      파일의 다운로드가 제대로 되지 않거나 파일형식에 맞는 프로그램으로 정상 작동하지 않는 경우 다른 자료와 70% 이상 내용이 일치하는 경우 (중복임을 확인할 수 있는 근거 필요함) 인터넷의 다른 사이트, 연구기관, 학교, 서적 등의 자료를 도용한 경우 자료의 설명과 실제 자료의 내용이 일치하지 않는 경우

“한국건축친환경설비학회 논문집”의 다른 논문도 확인해 보세요!

문서 초안을 생성해주는 EasyAI
안녕하세요 해피캠퍼스의 20년의 운영 노하우를 이용하여 당신만의 초안을 만들어주는 EasyAI 입니다.
저는 아래와 같이 작업을 도와드립니다.
- 주제만 입력하면 AI가 방대한 정보를 재가공하여, 최적의 목차와 내용을 자동으로 만들어 드립니다.
- 장문의 콘텐츠를 쉽고 빠르게 작성해 드립니다.
- 스토어에서 무료 이용권를 계정별로 1회 발급 받을 수 있습니다. 지금 바로 체험해 보세요!
이런 주제들을 입력해 보세요.
- 유아에게 적합한 문학작품의 기준과 특성
- 한국인의 가치관 중에서 정신적 가치관을 이루는 것들을 문화적 문법으로 정리하고, 현대한국사회에서 일어나는 사건과 사고를 비교하여 자신의 의견으로 기술하세요
- 작별인사 독후감
  • 전문가요청 배너
해캠 AI 챗봇과 대화하기
챗봇으로 간편하게 상담해보세요.
2025년 10월 18일 토요일
AI 챗봇
안녕하세요. 해피캠퍼스 AI 챗봇입니다. 무엇이 궁금하신가요?
9:47 오후